Part Number Hot Search : 
0ANGBAML XC6365 MPS394 RF237606 30L30C Z2SMA109 PD78081A BZX79
Product Description
Full Text Search
 

To Download GNAMG0233P32 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Special Encoders & Sensors
Sensing range 15, 30, 60, 360 CANopen / Profibus-DP
GNAMG
Features - Inclination sensor / CANopen / Profibus - Measuring range two-dimensional: 15, 30 and 60 - Measuring range one-dimensional: 360 - Resolution: 0.001 to 1 - Precision: 0.1 to 0.5 - Programmable parameters - Protection IP 66 Optional - Stainless steel GNAMG with mounting plate 99 x 60 mm Technical data - electrical ratings Voltage supply Consumption w/o load Initializing time (typ.) Interfaces User address Measuring range Resolution 10...30 VDC 100 mA (24 VDC) 250 ms after power on CANopen, Profibus-DPV0 Rotary switch in bus cover 15, 30, 60 (two-dimensional) 360 (one-dimensional) 0.001...1 (measuring range 15) 0.01...1 (measuring range 30) 0.01...1 (measuring range 60) 0.1...1 (measuring range 360) 0.1 (measuring range 15) 0.2 (measuring range 30) 0.5 (measuring range 60) 0.5 (measuring range 360) 0.5 s 10 Hz Binary DIN EN 61000-6-2 DIN EN 61000-6-4 Resolution Preset and offset Moving average filter Parameter error DUO-LED integrated in bus cover UL approval / E63076 Reverse polarity protection Yes Technical data - mechanical design Housing Protection DIN EN 60529 Materials Operating temperature Relative humidity Resistance Mounting plate with bus cover IP 66 Bus cover: zinc die-cast Mounting plate: aluminium -25...+85 C -40...+85 C (optional) 95 % non-condensing DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms 250 g Cable gland or connector M12
Subject to modification in technic and design. Errors and omissions excepted.
Dimensions mounting plate 99 x 60 x 5 mm
Weight approx. E-connection
Accuracy
Build-up time max. Measuring cycle Code Interference immunity Emitted interference Programmable parameters Diagnostic function Status indicator Approval
1
www.baumerivo.com
29/10/2008
Special Encoders & Sensors
Sensing range 15, 30, 60, 360 CANopen / Profibus-DP
GNAMG
Part number GNAMG. 0 Interface CANopen / cable gland CANopen / connector M12 Profibus-DPV0 / cable gland Profibus-DPV0 / connector M12 Accessories Connectors and cables (page %S) Z 180.005 Z 180.007 Z 181.005 5P32 5PA2 3P32 3PA2 Female connector M12, 5-pin, 5 m cable Female connector M12, 5-pin, 10 m cable Cable connector M12, 5-pin, 5 m cable Connection M2 / M3, continuative bus CD with describing files & manuals
Programming accessories (page %S) Z 150.022
21 22 23 15
Measuring range Dual axes 15 Dual axes 30 Dual axes 60 Single axis 360 (no end stop)
Terminal assignment CANopen - M12 connector Connector Assignment Description Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 5 4 1 GND UB - CAN_H CAN_L 5 4 33 2 2 1 Ground connection relating to UB Voltage supply 10...30 VDC - CAN bus signal (dominant High) CAN bus signal (dominant Low) M12 connector (male / female) A-coded
Housing 0 Bus cover with mounting plate 99 x 60 mm CD with file descriptions is not included in the delivery. You may order them on CD as accessory free-of-charge.
Profibus - M12 connector Pin 1 Pin 3 4 3 1 Pin 2 Pin 4 5 4 1 2 A B 3 3 5 4 1 Negative data line Positive data line M12 connector (male / female) B-coded UB GND Voltage supply 10...30 VDC Ground connection relating to UB M12 connector (male) A-coded
22
Terminals of the same significance are internally connected and identical in their functions. Max. load on the internal terminal connections UB-UB and GND-GND is 1 A each.
2
www.baumerivo.com
29/10/2008
Subject to modification in technic and design. Errors and omissions excepted.
Special Encoders & Sensors
Sensing range 15, 30, 60, 360 CANopen / Profibus-DP
GNAMG
Installation position Measuring range 15, 30, 60 The two-dimensional inclination sensor with a configured range of 15, 30 and 60 must be mounted with the base plate in horizontal position, i.e. parallel to the horizontal line. The inclination sensor may also be installed upside down, i.e. turned by 180. The sensor can be inclined both towards the X and Y axis at the same time. For each axis a separate measured value is provided. Default on delivery the inclination sensor will apply the selected sensing range to both axis, for example 15 with the zero passage being precisely in the horizontal line.
Default 0 Measuring range 360
Measured inclination -30
Default 0
Measured inclination 30
The inclination sensor with a configured range of 360 must be mounted in a way that the X-axis as in the following sketch is directed in a parallel way towards gravity. The deflection may not be more than 3. Y Z + X Please note also that the inclination sensor must evenly touch the contact surface and during inclination/rotation must not be subject to any inclination in X- or Y-direction since this would have a negative impact on the measuring accuracy. The 360 inclination sensor default position is 0 as shown in the following illustration but may be configured at will by help of the preset function. The measuring direction may also be inverted. Default on delivery the inclination sensor's sensing direction is clockwise from 0...360, in case of active inversion counter-clockwise.
Subject to modification in technic and design. Errors and omissions excepted. 29/10/2008
Default 0
Measured inclination 45
Measured inclination 135
Measured inclination 180
3
www.baumerivo.com
Special Encoders & Sensors
Sensing range 15, 30, 60, 360 CANopen / Profibus-DP
GNAMG
Dimensions GNAMG cable gland
45 60 5 37.5 5.3(5x)
1
y+ x- x+ y-
36.3
60 24.5
23
63
CANopen connector M12
60
Profibus connector M12
60
63
63
75 99
4
www.baumerivo.com
29/10/2008
Subject to modification in technic and design. Errors and omissions excepted.


▲Up To Search▲   

 
Price & Availability of GNAMG0233P32

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X